| /* SPDX-License-Identifier: GPL-2.0-only */ |
| |
| Device (BAT) |
| { |
| Name (_HID, EisaId ("PNP0C0A")) |
| Name (_UID, 1) |
| Name (_PCL, Package () { \_SB }) |
| |
| Name (PBIF, Package () { |
| 0x00000001, /* 0x00: Power Unit: mAh */ |
| 0xFFFFFFFF, /* 0x01: Design Capacity */ |
| 0xFFFFFFFF, /* 0x02: Last Full Charge Capacity */ |
| 0x00000001, /* 0x03: Battery Technology: Rechargeable */ |
| 0xFFFFFFFF, /* 0x04: Design Voltage */ |
| 0x00000003, /* 0x05: Design Capacity of Warning */ |
| 0xFFFFFFFF, /* 0x06: Design Capacity of Low */ |
| 0x00000001, /* 0x07: Capacity Granularity 1 */ |
| 0x00000001, /* 0x08: Capacity Granularity 2 */ |
| "S10", /* 0x09: Model Number */ |
| "", /* 0x0a: Serial Number */ |
| "LION", /* 0x0b: Battery Type */ |
| "TPS" /* 0x0c: OEM Information */ |
| }) |
| |
| Name (PBIX, Package () { |
| 0x00000000, // 0x00: Revision |
| 0x00000001, // 0x01: Power Unit: mAh |
| 0xFFFFFFFF, // 0x02: Design Capacity |
| 0xFFFFFFFF, // 0x03: Last Full Charge Capacity |
| 0x00000001, // 0x04: Battery Technology: Rechargeable |
| 0xFFFFFFFF, // 0x05: Design Voltage |
| 0x00000003, // 0x06: Design Capacity of Warning |
| 0xFFFFFFFF, // 0x07: Design Capacity of Low |
| 0x00000000, // 0x08: Cycle Count |
| 0x00018000, // 0x09: Measurement Accuracy (98.3%?) |
| 0x000001F4, // 0x0a: Max Sampling Time (500ms) |
| 0x0000000a, // 0x0b: Min Sampling Time (10ms) |
| 0xFFFFFFFF, // 0x0c: Max Averaging Interval |
| 0xFFFFFFFF, // 0x0d: Min Averaging Interval |
| 0x00000001, // 0x0e: Capacity Granularity 1 |
| 0x00000001, // 0x0f: Capacity Granularity 2 |
| "S10", // 0x10: Model Number |
| "", // 0x11: Serial Number |
| "LION", // 0x12: Battery Type |
| "TPS" // 0x13: OEM Information |
| }) |
| |
| Name (PBST, Package () { |
| 0x00000000, /* 0x00: Battery State */ |
| 0xFFFFFFFF, /* 0x01: Battery Present Rate */ |
| 0xFFFFFFFF, /* 0x02: Battery Remaining Capacity */ |
| 0xFFFFFFFF, /* 0x03: Battery Present Voltage */ |
| }) |
| Name (BSTP, Zero) |
| |
| /* Battery Capacity warning at 15% */ |
| Name (DWRN, 15) |
| |
| /* Battery Capacity low at 10% */ |
| Name (DLOW, 10) |
| |
| /* Workaround for full battery status, enabled by default */ |
| Name (BFWK, One) |
| |
| /* Method to enable full battery workaround */ |
| Method (BFWE) |
| { |
| BFWK = 1 |
| } |
| |
| /* Method to disable full battery workaround */ |
| Method (BFWD) |
| { |
| BFWK = 0 |
| } |
| |
| Method (_STA, 0, Serialized) |
| { |
| If (BTEX) { |
| Return (0x1F) |
| } Else { |
| Return (0x0F) |
| } |
| } |
| |
| Method (_BIF, 0, Serialized) |
| { |
| /* Last Full Charge Capacity */ |
| PBIF [2] = BTDF |
| |
| /* Design Voltage */ |
| PBIF [4] = BTDV |
| |
| /* Design Capacity */ |
| Local0 = BTDA |
| PBIF [1] = Local0 |
| |
| /* Design Capacity of Warning */ |
| Local2 = (Local0 * DWRN) / 100 |
| PBIF [5] = Local2 |
| |
| /* Design Capacity of Low */ |
| Local2 = (Local0 * DLOW) / 100 |
| PBIF [6] = Local2 |
| |
| Return (PBIF) |
| } |
| |
| Method (_BIX, 0, Serialized) |
| { |
| /* Last Full Charge Capacity */ |
| PBIX [3] = BTDF |
| |
| /* Design Voltage */ |
| PBIX [5] = BTDV |
| |
| /* Design Capacity */ |
| Local0 = BTDA |
| PBIX [2] = Local0 |
| |
| /* Design Capacity of Warning */ |
| Local2 = (Local0 * DWRN) / 100 |
| PBIX [6] = Local2 |
| |
| /* Design Capacity of Low */ |
| Local2 = (Local0 * DLOW) / 100 |
| PBIX [7] = Local2 |
| |
| Return (PBIX) |
| } |
| |
| Method (_BST, 0, Serialized) |
| { |
| /* |
| * 0: BATTERY STATE |
| * |
| * bit 0 = discharging |
| * bit 1 = charging |
| * bit 2 = critical level |
| */ |
| |
| /* Check if AC is present */ |
| If (ACEX) { |
| /* Read battery status from EC */ |
| Local0 = BSTS |
| } Else { |
| /* Always discharging when on battery power */ |
| Local0 = 0x01 |
| } |
| |
| /* Check for critical battery level */ |
| If (BFCR) { |
| Local0 |= 0x04 |
| } |
| PBST [0] = Local0 |
| |
| /* Notify if battery state has changed since last time */ |
| If (Local0 != BSTP) { |
| BSTP = Local0 |
| Notify (BAT, 0x80) |
| } |
| |
| /* |
| * 1: BATTERY PRESENT RATE |
| */ |
| Local1 = BTPR |
| If (Local1 & 0x8000) { |
| Local0 = ~Local1 & 0x7FFF |
| Local0++ |
| } Else { |
| Local0 = Local1 & 0x7FFF |
| } |
| If(Local0 < 0x0352) |
| { |
| Local0 = 0x0352 |
| } |
| PBST [1] = Local0 |
| |
| /* |
| * 2: BATTERY REMAINING CAPACITY |
| */ |
| Local0 = BTRA |
| If (BFWK && ACEX && !BSTS) { |
| Local1 = BTDF |
| |
| /* See if within ~6% of full */ |
| Local2 = Local1 >> 4 |
| If ((Local0 > (Local1 - Local2)) && (Local0 < (Local1 + Local2))) |
| { |
| Local0 = Local1 |
| } |
| } |
| PBST [2] = Local0 |
| |
| /* |
| * 3: BATTERY PRESENT VOLTAGE |
| */ |
| PBST [3] = BTVO |
| |
| Return (PBST) |
| } |
| } |