| /* SPDX-License-Identifier: GPL-2.0-only */ |
| |
| Device (TCHG) |
| { |
| Name (_HID, "INT3403") |
| Name (_UID, 0) |
| Name (PTYP, 0x0B) |
| Name (_STR, Unicode("Battery Charger")) |
| |
| Method (_STA) |
| { |
| If (\DPTE == 1) { |
| Return (0xF) |
| } Else { |
| Return (0x0) |
| } |
| } |
| |
| /* Return charger performance states defined by mainboard */ |
| Method (PPSS) |
| { |
| Return (\_SB.CHPS) |
| } |
| |
| /* Return maximum charger current limit */ |
| Method (PPPC) |
| { |
| /* Convert size of PPSS table to index */ |
| Local0 = SizeOf (\_SB.CHPS) |
| Local0-- |
| |
| /* Check if charging is disabled (AC removed) */ |
| If (\_SB.PCI0.LPCB.EC0.ACEX == Zero) { |
| /* Return last power state */ |
| Return (Local0) |
| } Else { |
| /* Return highest power state */ |
| Return (0) |
| } |
| |
| Return (0) |
| } |
| |
| /* Set charger current limit */ |
| Method (SPPC, 1) |
| { |
| /* Retrieve Control (index 4) for specified PPSS level */ |
| Local0 = DerefOf (DerefOf (\_SB.CHPS[ToInteger (Arg0)])[4]) |
| |
| /* Pass Control value to EC to limit charging */ |
| \_SB.PCI0.LPCB.EC0.CHGS (Local0) |
| } |
| |
| /* Initialize charger participant */ |
| Method (INIT) |
| { |
| /* Disable charge limit */ |
| \_SB.PCI0.LPCB.EC0.CHGD () |
| } |
| } |