treewide: Remove "ERROR: "/"WARN: " prefixes from log messages

Now that the console system itself will clearly differentiate loglevels,
it is no longer necessary to explicitly add "ERROR: " in front of every
BIOS_ERR message to help it stand out more (and allow automated tooling
to grep for it). Removing all these extra .rodata characters should save
us a nice little amount of binary size.

This patch was created by running

  find src/ -type f -exec perl -0777 -pi -e 's/printk\(\s*BIOS_ERR,\s*"ERROR: /printk\(BIOS_ERR, "/gi' '{}' ';'

and doing some cursory review/cleanup on the result. Then doing the same
thing for BIOS_WARN with

  's/printk\(\s*BIOS_WARNING,\s*"WARN(ING)?: /printk\(BIOS_WARNING, "/gi'

Signed-off-by: Julius Werner <jwerner@chromium.org>
Change-Id: I3d0573acb23d2df53db6813cb1a5fc31b5357db8
Reviewed-on: https://review.coreboot.org/c/coreboot/+/61309
Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
Reviewed-by: HAOUAS Elyes <ehaouas@noos.fr>
Reviewed-by: Lance Zhao
Reviewed-by: Jason Glenesk <jason.glenesk@gmail.com>
diff --git a/src/vendorcode/eltan/security/verified_boot/vboot_check.c b/src/vendorcode/eltan/security/verified_boot/vboot_check.c
index ed20af5..09da5c5 100644
--- a/src/vendorcode/eltan/security/verified_boot/vboot_check.c
+++ b/src/vendorcode/eltan/security/verified_boot/vboot_check.c
@@ -36,13 +36,13 @@
 
 	buffer = cbfs_map(RSA_PUBLICKEY_FILE_NAME, &size);
 	if (!buffer || !size) {
-		printk(BIOS_ERR, "ERROR: Public key not found!\n");
+		printk(BIOS_ERR, "Public key not found!\n");
 		goto fail;
 	}
 
 	if ((size != CONFIG_VENDORCODE_ELTAN_VBOOT_KEY_SIZE) ||
 	    (buffer != (void *)CONFIG_VENDORCODE_ELTAN_VBOOT_KEY_LOCATION)) {
-		printk(BIOS_ERR, "ERROR: Illegal public key!\n");
+		printk(BIOS_ERR, "Illegal public key!\n");
 		goto fail;
 	}
 
@@ -53,7 +53,7 @@
 	if ((sd->workbuf_used + size + sizeof(struct vb2_kernel_preamble) +
 	    ((CONFIG_VENDORCODE_ELTAN_OEM_MANIFEST_ITEMS * DIGEST_SIZE) + (2048/8))) >
 	    sizeof(wb_buffer)) {
-		printk(BIOS_ERR, "ERROR: Work buffer too small\n");
+		printk(BIOS_ERR, "Work buffer too small\n");
 		goto fail;
 	}
 
@@ -74,7 +74,7 @@
 	/* Fill body_signature (vb2_structure). RSA2048 key is used */
 	cbfs_map("oemmanifest.bin", &size);
 	if (size != ((CONFIG_VENDORCODE_ELTAN_OEM_MANIFEST_ITEMS * DIGEST_SIZE) + (2048/8))) {
-		printk(BIOS_ERR, "ERROR: Incorrect manifest size!\n");
+		printk(BIOS_ERR, "Incorrect manifest size!\n");
 		goto fail;
 	}
 	pre->body_signature.data_size = CONFIG_VENDORCODE_ELTAN_OEM_MANIFEST_ITEMS *