mb/google/volteer/var/lindar: Increase Goodix touchscreen reset delay to 180 ms

1. Follow GT7375P Programming Guide_Rev.0.6 to increase
   reset delay to 180ms.

BUG=b:181711141
TEST=Build and boot lindar to OS.

Signed-off-by: Kevin Chang <kevin.chang@lcfc.corp-partner.google.com>
Change-Id: I82222ca094eead7e9e691857e128243cfe7c310e
Reviewed-on: https://review.coreboot.org/c/coreboot/+/51739
Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
Reviewed-by: Zhuohao Lee <zhuohao@google.com>
Reviewed-by: Tim Wawrzynczak <twawrzynczak@chromium.org>
diff --git a/src/mainboard/google/volteer/variants/lindar/overridetree.cb b/src/mainboard/google/volteer/variants/lindar/overridetree.cb
index 3140b85..139cd99 100644
--- a/src/mainboard/google/volteer/variants/lindar/overridetree.cb
+++ b/src/mainboard/google/volteer/variants/lindar/overridetree.cb
@@ -103,8 +103,8 @@
 				register "generic.probed" = "1"
 				register "generic.reset_gpio" =
 							"ACPI_GPIO_OUTPUT_ACTIVE_LOW(GPP_C10)"
-				# Parameter T3 >= 10ms
-				register "generic.reset_delay_ms" = "120"
+				# Parameter T5 >= 180ms
+				register "generic.reset_delay_ms" = "180"
 				# Parameter T2 >= 1ms
 				register "generic.reset_off_delay_ms" = "3"
 				register "generic.enable_gpio" = "ACPI_GPIO_OUTPUT_ACTIVE_HIGH(GPP_A8)"