mb/siemens/mc_ehl5: Set LVDS re-power delay to 1 s

The currently used panel type could work with 500 ms but increasing
the value to 1 second allows to use a wider range of LVDS LCD panels,
as many of them specify the delay of 1 s as minimum.

The patch has already been made for mc_ehl3 and serves the purpose of
standardization.
commit c0221aa980d3 ("mb/siemens/mc_ehl3/lcd_panel.c: Set LVDS re-power
delay to 1 s")

Change-Id: Ife26ff27b41298ceeed7d9aed0c1ae5553ab5ff8
Signed-off-by: Mario Scheithauer <mario.scheithauer@siemens.com>
Reviewed-on: https://review.coreboot.org/c/coreboot/+/80214
Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
Reviewed-by: Jan Samek <jan.samek@siemens.com>
diff --git a/src/mainboard/siemens/mc_ehl/variants/mc_ehl5/lcd_panel.c b/src/mainboard/siemens/mc_ehl/variants/mc_ehl5/lcd_panel.c
index f3c5bd5..0d189a3 100644
--- a/src/mainboard/siemens/mc_ehl/variants/mc_ehl5/lcd_panel.c
+++ b/src/mainboard/siemens/mc_ehl/variants/mc_ehl5/lcd_panel.c
@@ -82,8 +82,8 @@
 	cfg->t2_delay = 0x01;
 	/* LVDS to backlight active delay: 200 ms */
 	cfg->t3_timing = 0x04;
-	/* Minimum re-power delay: 500 ms */
-	cfg->t12_timing = 0x0a;
+	/* Minimum re-power delay: 1 s */
+	cfg->t12_timing = 0x14;
 	/* Backlight off to LVDS inactive delay: 200 ms */
 	cfg->t4_timing = 0x04;
 	/* Enable LVDS to VDD inactive delay. */